Fault code

INVT GD270 OUt2 Inverter unit V-phase protection

Diagnostic context

What OUt2 means on INVT GD270

OUt2 indicates V-phase inverter-unit protection. The manufacturer lists interference, poor drive-wire connections and a to-ground short circuit as possible causes.

Operating context: Inspect the drive wiring first and confirm that its connections are secure. The manufacturer also directs a check for strong interference around peripheral equipment.

This diagnostic context is an editorial explanation. The possible causes and recommended checks below are the verified manufacturer troubleshooting content.

Possible causes

  • Misoperation caused by interference.
  • Drive wires connected poorly.
  • To-ground short circuit occurred.

Recommended checks and actions

  • Check drive wires.
  • Check whether there is strong interference surrounding the peripheral device.

Technical source

INVT GD270 Manual EN - Fault OUt2 — page 277