Fault code

INVT GD270 F1-Er Failed to identify the expansion card at card slot 1

Diagnostic context

What F1-Er means on INVT GD270

F1-Er indicates that data transmission exists at card slot 1 but the drive cannot identify the installed expansion-card type.

Operating context: Verify that the expansion card is supported. With power removed, stabilize the card interface and inspect the insertion port for damage before the next power-on.

This diagnostic context is an editorial explanation. The possible causes and recommended checks below are the verified manufacturer troubleshooting content.

Possible causes

  • There is data transmission in interfaces of card slot 1, however, it cannot read the card type.

Recommended checks and actions

  • Check whether the expansion card at this slot is supported.
  • Stabilize the expansion card interfaces after power-off, and check whether the fault persists at next power-on.
  • Check whether the insertion port is damaged, if yes, replace the insertion port after power-off.

Technical source

INVT GD270 Manual EN - Fault F1-Er — page 281