Fault code
INVT GD20 ItE Current detection fault
Diagnostic context
What ItE means on INVT GD20
ItE is the GD20 current detection fault. The manufacturer lists the connection of the control board is not good. as one of the documented causes.
Operating context:
Start with the manufacturer troubleshooting sequence. Check the connector and repatch. Change the Hoare.
This diagnostic context is an editorial explanation. The possible causes and recommended checks below are the verified manufacturer troubleshooting content.
Possible causes
- The connection of the control board is not good
- Assistant power is bad
- Hoare components is broken
- The modifying circuit is abnormal.
Recommended checks and actions
- Check the connector and repatch
- Change the Hoare
- Change the main control panel
Technical source
INVT GD20 Manual EN - P07.27 Current fault type — page 62
INVT GD20 Manual EN - Fault tracking — page 95
Manual tiếng Việt INVT GD20 - Xử lý lỗi — page 84