Fault code

Inovance MD280 Err23 Short circuit to ground

Diagnostic context

What Err23 means on Inovance MD280

Err23 is the MD280 short circuit to ground. The manufacturer associates this fault with the motor is short circuited to the ground.

Operating context: Start with the manufacturer troubleshooting step: Replace the cable or motor.

This diagnostic context is an editorial explanation. The possible causes and recommended checks below are the verified manufacturer troubleshooting content.

Possible causes

  • The motor is short circuited to the ground.

Recommended checks and actions

  • Replace the cable or motor.

Technical source

Inovance MD280 User Manual EN - Err23 troubleshooting — page 162

Inovance MD280 troubleshooting VI - Err23 — page 11